Privacy choices

Choose what we may use.

The site works without optional tracking. Your choice is saved on this device and can be changed here anytime.

Necessary

Runs the site, protects forms, and remembers this privacy choice.

Always on

Lighting retrofits

LED Parking Lot Lighting Retrofit Leads and Payback (2026)

Build an electrical sales territory around properties with parking. Price a 24-fixture retrofit, document the savings, and reach the person who approves the work.

The short answer

For LED parking lot lighting retrofit leads, start with commercial properties that have paved parking areas, then verify fixture wattage and operating hours during a survey. Ground Control by PorchRocket supplies matching properties by area, business type and building size for $10 to $20 per building, within 48 hours after payment. Sell the owner a documented payback calculation with current utility incentives. Keep outdoor pole lighting out of a Section 179D deduction pitch.

Find lots to relight

What matters most

  • The 24-fixture model saves $5,943.82 annually and pays back a $28,920 installation in about 4.9 years before rebates.
  • Ground Control costs $10 to $20 per commercial building and delivers the property file within 48 hours after payment.
  • Section 179D covers qualifying building systems, including interior lighting, and excludes property whose construction begins after June 30, 2026.
  • Budgeting $5,666 for data, outreach and estimating produces a $2,833 acquisition cost if two accounts sign.

Say you quote $28,920 to replace 24 pole-mounted fixtures at a 62,000 square foot retail center. With each fixture dropping from 458 watts to 150 watts, 4,200 operating hours a year and electricity at $0.147 per kWh, energy savings reach $4,563.82 annually. Add $1,380 in net maintenance savings and the owner’s simple payback is 4.9 years before rebates. The project and sales campaign below use planning assumptions.

Start with the owner’s records. Ask for the fixture inventory and service invoices, then sit down with the manager who knows when the lights run so you can distinguish the operating schedule from the setting left on a time clock. Show how the dollars change when hours or electricity prices change. A rebate belongs on its own line, backed by the serving utility’s approval.

Ground Control by PorchRocket gets your sales team to the property: commercial buildings with paved parking areas, selected by business type and building size inside your territory. Your survey supplies the lighting details. Build the prospect list around buildings worth that visit, and track what each signed account earns after installation and sales costs.

How much can 24 LED parking lot lights save?

A 24-fixture conversion from 458 watts to 150 watts saves 31,046.4 kWh annually at 4,200 operating hours, worth $4,563.82 at the assumed rate.

The calculation uses system input power. DOE’s parking lot lighting design guide distinguishes lamp-plus-ballast watts from lamp wattage and treats LED input as the fixture with its driver. For your quote, pull the documentation for each fixture type and replace the 458-watt assumption with that equipment’s system input, preserving the source beside the number so the reviewer can check it.

Energy calculation Existing lighting Proposed lighting
Fixtures 24 24
Input watts per fixture 458 150
Connected load 10.992 kW 3.600 kW
Annual operating hours 4,200 4,200
Annual electricity 46,166.4 kWh 15,120 kWh
Electricity cost at $0.147 per kWh $6,786.46 $2,222.64

The arithmetic is 24 × (458 − 150) × 4,200 ÷ 1,000 = 31,046.4 kWh saved. Multiply by $0.147 to get $4,563.82. That rate is an assumption; replace it with the customer’s applicable energy charge.

Maintenance needs its own calculation. Against the old lighting’s assumed $2,340 annual service bill, put a new budget of $960 consisting of a $540 inspection agreement plus $420 held for repairs the agreement does not cover. The net maintenance saving is $1,380. Energy and maintenance together produce $5,943.82.

Read several years of invoices before setting the baseline, because an isolated repair after a delivery truck hits a pole should not become a recurring annual saving in the owner’s replacement budget. Keep collision repairs separate. GSA’s lighting and controls guidance specifically identifies access equipment as a reason exterior maintenance can be expensive.

Keep two versions of the payback on the proposal. Energy alone returns the $28,920 investment in 6.3 years. Energy plus the documented maintenance reduction returns it in 4.9. An owner who cannot substantiate the maintenance saving can still see the energy case.

What does a parking lot lighting retrofit cost?

The worked 24-fixture project sells for $28,920, or $1,205 per fixture installed, against $20,340 in direct job costs.

Build the price from the scope. This budget assumes replacement fixtures on retained poles, with existing circuits suitable for the specified work after inspection. Material and project allowances include freight and applicable purchase taxes. If the survey calls for new poles or underground work, send those quantities back to the estimator before issuing a firm price so the owner sees the cost of the work you intend to perform.

Contractor budget item Calculation or allowance Direct cost
Fixtures and mounting hardware 24 × $420 $10,080
Installation labor 84 person-hours × $76 loaded cost $6,384
Lift and site protection Project allowance $1,520
Layout and controls setup Project allowance $1,380
Permits, disposal and closeout Project allowance $976
Total direct job cost Sum of the five rows $20,340
Gross profit $28,920 − $20,340 $8,580

Count person-hours, including the second electrician. Two electricians working eight hours use 16 person-hours, and the 84-hour allowance in this budget already includes loading and installation travel, with each hour priced at the assumed $76 cost including labor burden.

Gross margin is $8,580 ÷ $28,920 = 29.7%. Office overhead and customer acquisition still come out of that gross profit. The contractor gross margin guide explains how to keep the job budget separate from the company’s final profit.

Get supplier quotes for the exact fixture and mounting combination before committing the material allowance, and tie the proposal’s expiration date to those prices so your estimator knows when to request a fresh quote. Reprice every extra mobilization. If the owner wants phased installation, the estimate needs the crew’s loading and travel time for each return.

Where an inspection leaves a repair unresolved, I would show an allowance with its own scope and explain how unused money is handled, giving the owner enough detail to compare that part of competing proposals. Agree on approval before dispatch. Put the person authorized to approve extra work on the project contact sheet.

Payback under low, base and high savings

The same $28,920 installation pays back in about 3.8 to 7.5 years when annual hours and energy prices change across the scenarios below.

Simple payback equals net installed cost divided by annual savings. Hold the $1,380 maintenance saving constant while changing the energy rate and operating hours below, so the owner can see those two inputs’ effect before introducing any rebate or changing the installation scope. Financing and taxes stay outside this calculation.

Savings case Hours per year Energy rate Annual energy savings Energy plus maintenance savings Simple payback
Low 3,200 $0.105/kWh $2,483.71 $3,863.71 7.5 years
Base 4,200 $0.147/kWh $4,563.82 $5,943.82 4.9 years
High 4,500 $0.185/kWh $6,153.84 $7,533.84 3.8 years

Ask the owner for the investment hurdle before designing the final package. If the hurdle is five years, the base case clears it by a small amount. The low case needs a smaller installed cost, an approved incentive or a different scope. Do not stretch the operating schedule to make the spreadsheet pass.

Controls deserve a separate option. DOE’s exterior lighting purchasing guidance describes controls that adjust lighting to conditions and activity. For this project, reducing input from 150 watts to 75 watts during 1,800 of the existing annual hours would save another 3,240 kWh, or $476.28 annually.

Price the extra controls against the owner’s approved operating sequence, calculating savings from the new LED load so the estimate does not take a second credit for electricity already removed by the fixture conversion. Count each saved kWh once. Leave unverified demand-charge savings out of the proposal and use the customer’s tariff to determine which bill items change.

Utility rebates for parking lot lighting in 2026

Check the serving utility before ordering equipment; Tacoma Public Utilities’ 2026 general business program lists $0.17 per kWh saved and requires approval before starting.

Tacoma’s Bright Rebates program caps that general business incentive at 60 percent of eligible installed cost. Eligible upgrades include HID-to-LED conversions. The program requires a qualifying business electric account and approved product listings. Its terms belong to that territory, so use its rate only for a project the program accepts.

Applied to the model’s 31,046.4 kWh reduction, $0.17 per kWh would produce $5,277.89 if the program approves that savings quantity and the project qualifies. Assuming the full $28,920 qualifies as eligible installed cost, the 60 percent cap is $17,352, above the calculated incentive. Net capital cost becomes $23,642.11, giving about 4.0 years of payback at $5,943.82 in annual savings.

That incentive is a one-time payment. Do not add it to annual savings.

Give each prospect a rebate record identifying the electric account and the person filing the application, with the program year and submission deadline beside the estimate so the project manager can check the next action. Keep the approved baseline there too. If the program approves a smaller savings quantity, update the owner’s financial sheet before asking for a signature.

Use the DesignLights Consortium Qualified Products Lists when the utility requires a DLC-listed product. Save the exact listing with the fixture schedule and record the model number with its selected options in the purchase order, so a purchasing substitution gets flagged for an eligibility check before anyone installs it.

Give the project manager a short rebate handoff:

  • The application status and written notice authorizing the next step.
  • The equipment schedule approved for the incentive.
  • The evidence to collect before removal and after installation.
  • The named person who files invoices and resolves program questions.

In the proposal, show the full contract amount and any expected rebate as separate figures. State who receives the payment. The contractor’s price should remain understandable if the owner reads the financial page without the incentive attachment.

Does Section 179D apply to outdoor parking lot lighting?

Outdoor pole lighting is outside Section 179D’s listed building systems, and the deduction excludes property whose construction begins after June 30, 2026.

The IRS eligibility page lists interior lighting, qualifying HVAC and hot-water systems, and the building envelope. That scope does not support assigning a 179D deduction to this outdoor parking-lot retrofit.

The timing changed too. DOE’s current 179D explanation identifies the July 4, 2025 law that added the construction-start cutoff. A new November 2026 proposal should not present the deduction as an incentive available for newly started work. Earlier-started qualifying building projects require their own eligibility review.

For a combined building-and-lot project, keep the outdoor quantities on a separate schedule. Send the owner an itemized scope so their tax adviser can evaluate any eligible building work independently. The outdoor payback above uses zero tax benefit.

I would remove a promised 179D saving from the first sales sheet, before the owner circulates it for budget approval. Correcting an attractive payback after the facilities manager has presented it to finance creates another round of review. Lead with the energy reduction and the approved utility program.

Which properties make the best retrofit prospects?

I would start with retail centers, industrial properties and larger multifamily sites where a substantial parking area justifies a scheduled lighting survey.

Choose a business type your crew can serve repeatedly. For a first campaign, I would rather price comparable retail lots in one territory than alternate between a small office courtyard and a large freight yard. The survey still determines the equipment and the work.

Property type First qualification question Evidence to request Reason to schedule or hold
Retail center Who approves common-area lighting spending? Electric bill and exterior service invoices Schedule after the capital approver is identified
Industrial or warehouse property Which parking zones operate overnight? Shift schedule and circuit schedule Prioritize a defined operating baseline
Multifamily property Who controls the parking-lighting budget? Management authorization and service history Schedule when access and approval are assigned
Hotel Which exterior areas need lighting throughout the night? Lighting schedule and existing fixture records Price around the approved guest-access plan
Office campus Can the owner phase work without repeated mobilizations? Site plan and budget calendar Hold if the budget review has no scheduled date

Give the sales rep two separate fields: property fit and project readiness. A building belongs in the first group when it meets your territory and service criteria; moving it toward a proposal takes an owner conversation and survey evidence, with a budget date you can work toward. Some good properties will wait until next year.

I would rank a prospect higher after the owner supplies service records and agrees to a survey review meeting. I would hold one that only wants an equipment price without identifying the site. Both choices protect estimating hours.

Use a simple internal score: two points each for a serviceable location, an approved survey, a known decision maker and a dated budget review. Add one point each for usable lighting records and a stated project goal. Work the eight-to-ten-point accounts first. Update the score after each conversation.

Building a parking-lot target list near your crew

Start with one service territory and two business types, then use paved parking areas and building-size bands to select properties for qualification.

In Ground Control, choose the area your electricians can reach economically and select retail or industrial buildings with paved parking. Start this campaign with a 25,000-plus-square-foot building band, then have the surveyor establish the lot dimensions and fixture schedule from the site plan or field visit before anyone assigns installation hours to the property. Keep the two measurements separate.

The parking-lot property list is the direct starting point. Add properties with industrial yards only if yard lighting fits your crew’s work. Keep those prospects in a separate group so a warehouse-yard estimate does not dictate the assumptions on a retail lot.

Use one row per service location and another field for the parent owner or management group. The parking-property hub connects this trade with other work sold to the same lots. Use the commercial prospect-list guide for the shared address and ownership structure.

Before booking the survey, I would use this call opening:

I handle parking-lot lighting projects in this area. Who approves the exterior lighting budget for this property? With permission, we can inventory the fixtures and price a replacement against your operating hours and recent service costs.

Once connected, ask who pays the electric bill and whether they can share the relevant rate and lighting schedule. Ask when the owner reviews capital projects. End with a proposed survey date and a separate time to review the findings.

Record the answer in the property row. With a manager who is not ready, agree on a follow-up tied to the budget date; with a willing owner who has several sites, ask which location to assess first and who can authorize the next survey. Put the agreed dates in the file.

How to find lighting retrofit leads, step by step

Run an eight-step campaign over 30 days, assigning a rep and an estimator to carry each property from selection through pricing and approval.

  1. Days 1 and 2: set the installation envelope. Choose the territory, business types and project sizes your crew can price. Write down the work requiring a separate estimate, including new poles or underground repairs. Assign one person to approve surveys outside that scope.
  2. Days 2 and 3: pull the properties. Order commercial buildings with paved parking areas in Ground Control, filtered by your business types and building-size bands. Data costs $10 to $20 a building, and the file arrives within 48 hours after payment. Orders start at 10 buildings.
  3. Days 4 and 5: organize the accounts. Group locations by owner or manager. Add owner information or decision-maker research at checkout where needed, or have your rep research the contacts. Record the capital approver and who can authorize site access.
  4. Days 6 through 12: qualify by conversation. Ask about operating hours, service spending and the budget timetable. Book a survey only after someone agrees to review its findings. Keep the electric account and serving utility attached to that specific address.
  5. Days 10 through 18: collect the baseline. Have the surveyor document the fixture inventory and lighting controls. Obtain equipment input watts and site measurements. Photograph equipment identifiers and mark unresolved items for the estimator to price or investigate.
  6. Days 15 through 22: price the proposed design. Obtain material quotes and build the labor allowance. Compare energy-only payback with the version including supported maintenance savings. Check the rebate application sequence before equipment purchase or installation.
  7. Days 22 through 27: review with the approver. Present the installation scope and low, base and high savings cases. Agree on access arrangements and any remaining decisions. Schedule the next decision instead of leaving the proposal with an unspecified follow-up.
  8. Days 28 through 30: review the campaign. Total the hours spent on outreach, surveys and proposals. Record signed work at expected gross profit. Compare the results by business type, then order the next group using the property criteria that produced qualified surveys.

Keep a short stop list beside that schedule: no access approval, no responsible buyer, missing baseline, or unresolved scope that changes the price. Assign an owner and a next action to each held prospect. A rep should be able to explain why a building is waiting without reopening an old email thread.

What to record during the lighting survey

Give the estimator a fixture-by-fixture inventory with documented electrical inputs, plus the design basis your lighting designer will use to judge the proposed layout.

DOE’s parking lot guide begins its design process with an equipment inventory and lighting needs. Give every fixture an identifier, then carry it from the field photos through the site sketch to the priced schedule so the estimator can resolve a question about one pole without sending the surveyor back. Keep the original survey notes.

Record at least these items:

  • Fixture count by type, with multiple heads on a pole recorded separately.
  • Equipment labels and documented system watts, plus the relevant circuit information and which fixtures operate.
  • Pole locations, mounting details and access needed for the proposed installation.
  • Existing schedules and controls, with the person who can authorize changes.
  • Conditions requiring a separate electrical or structural assessment before pricing.
  • Areas the owner wants evaluated, including entrances and pedestrian crossings.

Have the lighting designer document the proposed distribution and the light levels used to judge the result. GSA’s guidance emphasizes directionality and brightness in exterior LED design. I would require the proposal to identify the applicable local requirements and the owner’s operating needs, then attach a photometric layout showing how the selected fixtures address them.

Do not substitute a wattage comparison for that review. The project needs both an energy calculation and an accepted lighting layout. Get the owner’s approval of the intended operating sequence before assigning savings to late-night dimming.

EPA identifies metal halide and other HID lamps among mercury-containing bulbs and links to business disposal requirements. Assign the removal and recycling responsibilities in the scope. Include the cost in the estimate and retain the required disposal records.

Close the survey with unresolved items assigned to someone, including any fixture that could not be identified from accessible records and needs a return inspection before the estimator can select its replacement or price the labor. Book that inspection. Every unresolved item needs a priced scope or an explicit allowance.

A proposal the owner can approve

Put the $28,920 scope and its 4.9-year base payback on the first page, followed by the evidence supporting the price and savings.

Use the first page as a decision sheet. Identify the 24 fixtures being replaced and attach the approved controls sequence. Spell out the installation access agreed with the manager. Show the full contract price before presenting the incentive adjustment. List the decision needed from the owner and the date through which the proposal remains valid.

Give facilities the fixture schedule and site layout. Finance gets the energy calculation and service-cost comparison, with each input tied to a record or an allowance so the person reviewing the payback can find the supporting document without calling your estimator. Keep the installation schedule visible. Mark the work areas so tenants know which parking sections will be unavailable.

I would bring one recommended design and one priced alternative to the review, giving the owner a choice about an item such as dimming while keeping the meeting focused on a scope your crew can install. Price the option separately. Show its extra cost beside its annual saving.

Set acceptance tasks before installation: record the installed models, test the operating schedule, check the agreed light levels and train the person responsible for overrides. Deliver the warranty documents and a location-based fixture schedule with the closeout file. Ask the owner to nominate that operating contact when accepting the proposal.

At properties planning other parking work, coordinate the scope with the responsible contractors. The parking-lot striping guide and parking-lot sealcoating guide cover adjacent sales conversations. Use them to ask about the owner’s schedule. Keep each project’s approval and savings calculation separate.

For an electrical contractor also pursuing EV charger installation prospects, the same property relationship can support another assessment. Do not include a future charger project in the lighting payback or in signed backlog. Ask for permission to scope it after the lighting decision.

The sales math from 100 properties to two accounts

A campaign costing $5,666 has a $2,833 customer acquisition cost if two accounts sign, with $17,160 in gross profit from their first installations.

Customer acquisition cost, or CAC, divides all campaign sales spending by accounts won. Budget 100 properties representing 100 distinct buying accounts after grouping shared owners and managers. Each signed account starts with one $28,920 installation. Use a $15-per-building data allowance within Ground Control’s stated range; the rep handles contact research within the outreach hours below.

Campaign cost Assumption Amount
Property data 100 × $15 $1,500
Research and outreach 32 hours × $42 $1,344
Surveys 10 × 2 person-hours × $76 $1,520
Proposals 8 × 1.5 hours × $76 $912
Travel, mail and allocated sales software Campaign allowance $390
Total acquisition spending Sum $5,666

Work backward from two accounts: eight proposals at a 25% close rate, 10 surveys with 80% reaching proposal, and 25 conversations with 40% reaching survey. Reaching 25 of the 100 accounts assumes a 25% conversation rate. Overall conversion is 2%. Loaded hourly costs include labor burden; outreach hours include campaign management. The $390 allowance covers acquisition travel separately from installation travel.

With one signed account, $8,580 in first-project gross profit leaves $2,914 after campaign spending. Two leave $11,494. Zero leaves the $5,666 acquisition bill to recover through later work. Reserve that cash before starting the campaign.

Fit improves the return on the initial prospecting effort. Assume half of 100 broadly selected locations fail your property criteria. At 2% conversion among the remaining 50, the planning output is one account. Starting with 100 fitting properties makes it two. Both begin with 100 locations to work; the targeted campaign funds the additional surveys and proposals in the budget above.

Use the lead-list ROI calculator to replace the model with your company’s costs. Lead-list ROI equals gross profit from acquired accounts, minus data and outreach costs, divided by those acquisition costs. On the first two installations, that is ($17,160 − $5,666) ÷ $5,666 = about 203%.

My decision rule is to expand the territory after the first campaign produces qualified surveys and signed work within the acquisition budget. If conversations do not produce surveys, review the property criteria and the offer before buying a larger file.

Five-year account value and repeat work

An account buying three $28,920 retrofits over five years produces $25,740 in project gross profit before any inspection agreement is added.

Customer lifetime value measures the gross profit expected from the relationship over a chosen period. For this account, retain the $8,580 gross profit per installation and assume the owner awards two more comparable sites after the first. Count only three projects in five years.

The project component is 3 × $8,580 = $25,740. Add the inspection agreement on the first site at $540 annual revenue and $300 annual direct cost. Assume renewal in each of years 2 through 5: four paid service years contribute 4 × ($540 − $300) = $960. Service at the other two sites adds nothing to this calculation. Total account value becomes $26,700, before acquisition and office overhead, without discounting future cash flows. The owner’s separate $420 repair reserve stays outside this service revenue.

Two such accounts produce $53,400 in gross profit. That is 35.6 times the $1,500 property-data purchase. Including all $5,666 of campaign spending gives a five-year acquisition ROI of about 842%, and account value divided by CAC is $26,700 ÷ $2,833 = 9.4.

The repeat awards drive that increase. Keep future locations in the pipeline with their own survey and budget dates; count signed work separately. The first installations already carry the acquisition cost in the base case. Later projects add profit when the owner awards them.

Give the inspection agreement a bounded scope. Price replacement parts and extra lift visits separately, with response terms that your service department has agreed to support, so an owner requesting an urgent repair can see what the annual fee covers before dispatch. Record renewal dates per site.

Suppliers organizing a larger territory can use the building-product market-data guide to connect property selection with dealer coverage. For the contractor, I would start with the owner’s next property and a dated invitation to assess it.

Public parking-lot lighting bids

Use Bid Control for city, county and school lighting opportunities, then price the specified fixtures and submission requirements from each buyer’s bid documents.

Bid Control by PorchRocket for electrical contractors brings relevant opportunities, due dates and addenda together, with early project signs and past winning prices. The electrical government contracts guide explains that sales path. Keep the public pipeline alongside private owner outreach. Before committing estimating hours, read the site-visit instructions and the specified equipment schedule. Price any required light-level verification and commissioning work. Confirm whether an alternate fixture is permitted and how to submit it for review. Bid Team can work the estimate with you and handle the forms, portal accounts and deadlines. You make the final call on your number, sign and send.

Building your relighting territory with Ground Control

The fastest way to build a parking-lot lighting prospect list is Ground Control by PorchRocket, using paved parking areas, business type and building-size filters in your chosen territory. Commercial data costs $10 to $20 per building, with orders starting at 10. The CSV and Excel file arrives within 48 hours after payment, often sooner, with a reason each property matched. Owner information and decision-maker research are available as add-ons. Report wrong matches within 30 days for a credit back. These are target properties for your outreach; their owners have not requested quotes.

For this campaign, the Ground Control parking-property order gives your team:

  • A territory selected around the places your crew can serve, with business types matched to your installation work.
  • Properties with paved parking areas and the building-size bands you select for the first campaign.
  • A reason for each match, so the rep can connect the property criteria to the opening conversation.
  • Optional owner information and named decision-maker contacts, including role and contact details where found. Unfound contacts are not charged.
  • CSV and Excel files your team can load into its sales tools and extend with survey findings, proposal dates and account relationships.
  • The exact order price before payment, with custom requests available for several markets or requirements outside the standard filters.

Start with the buildings your crew wants to serve, put a defensible payback in front of the owner, and earn the next property on the account.

Questions people ask

Quick answers

What is the best way to find parking lot lighting retrofit leads?

Start with properties that have paved parking areas in your service territory, then qualify the lighting during a survey. Ground Control filters commercial buildings by business type, building size and visible property features. Add owner or decision-maker research when needed, then ask about operating hours, the electric account and capital spending authority.

How much does an LED parking lot lighting retrofit cost?

This guide budgets $28,920 for 24 replacement fixtures, or $1,205 per fixture installed, including project support and contractor gross profit. Price your own material quotes and crew hours. Existing poles, access, controls and any separately scoped electrical repairs determine the estimate; a fixture purchase price alone does not price the job.

How do I calculate parking lot lighting payback?

Divide installed cost after an approved rebate by annual energy and maintenance savings. Calculate energy savings as fixture count times watts reduced times annual operating hours, divided by 1,000, then multiplied by the applicable electricity rate. The worked example produces a 4.9-year payback before rebates, financing or tax effects.

Are utility rebates available for LED parking lot lights in 2026?

Yes, participating utilities offer lighting incentives in 2026. For each address, check the current program, accepted equipment and approval sequence before buying. Keep the application and approved savings calculation with the job file, and show any rebate separately from the full contract price.

Does Section 179D cover outdoor parking lot lighting?

No, outdoor pole lighting falls outside the listed qualifying building systems. The IRS identifies interior lighting among eligible systems and excludes property whose construction begins after June 30, 2026. Use a separate review for any qualifying building work; do not deduct an assumed 179D benefit from an outdoor retrofit quote.

Can aerial imagery identify old metal halide parking lot lights?

Use imagery to select properties with parking, then verify lamp type and system wattage from equipment records or an authorized survey. Ground Control supplies matching property prospects. Your electrician records fixture counts, controls and electrical conditions before the estimator selects equipment or calculates savings.

Should I replace fixtures or install LED retrofit kits?

I would compare both against the required light distribution, equipment compatibility and installed labor. For the worked project, the budget uses new fixtures. Accept a kit only after reviewing its documented compatibility with the existing assembly, its qualification under the utility program and the maintenance responsibility you are taking on.

Who approves a commercial parking lot lighting project?

Confirm the capital approver with the owner or property manager before preparing a detailed proposal. Also identify the electric account holder and the person arranging access. Ask whether one approval covers multiple properties. Put the survey findings and payback in front of the person authorized to commit the project budget.

Research file

Sources used in this guide

Sources are linked at the claim they support and collected here for auditability. Vendor features and prices can change; verify them before purchasing.

  1. Guide to FEMP-Designated Parking Lot LightingU.S. Department of Energy: 2013 design guide supporting system input watts and the survey process, not current efficiency thresholds; checked November 2026.
  2. LED Lighting and Controls Guidance for Federal BuildingsU.S. General Services Administration: September 2024 guidance on exterior maintenance costs, distribution and lighting design; checked November 2026.
  3. 2026 Bright Rebates lighting incentivesTacoma Public Utilities: General business incentive rate, project-cost cap, eligible upgrades and approval before installation; checked November 2026.
  4. Qualified Products ListsDesignLights Consortium: Searchable qualified commercial LED products and lighting controls; checked November 2026.
  5. Energy efficient commercial buildings deductionInternal Revenue Service: Eligible building systems and the June 30, 2026 construction-start cutoff for Section 179D; checked November 2026.
  6. 179D Energy Efficient Commercial Buildings Tax DeductionU.S. Department of Energy: July 4, 2025 law change and the distinction between eligible building systems and other equipment; checked November 2026.
  7. Purchasing Energy-Efficient Exterior LightingU.S. Department of Energy: Exterior lighting selection and controls that adjust output to conditions and activity; checked November 2026.
  8. Recycling and disposal of mercury-containing bulbsU.S. Environmental Protection Agency: Metal halide and other mercury-containing lamps, with links to business disposal requirements; checked November 2026.
Your next best move

Put the next lighting survey on a lot that fits.

Choose commercial properties with paved parking areas in your service territory. Ground Control sends the matched buildings with a reason for each match, with owner and decision-maker research available as add-ons.

Find lots to relight